DC Fans Common Specifications

DC Fans
 ■ Standard
Vibration Test : Conforms to JIS C 60068-2-6
  Amplitude: 1.5mm
  Frequency 10 to 55 Hz, 1 hour.
In each of the X, Y and Z directions.
Shock Test : Conforms to JIS C 60068-2-27
  Acceleration 981 m/s2*
  Application time 6ms.
Once each in the X, Y and Z directions.*
*)  1004KL, 1204KL, 1404KL, 1604KL, 1606KL, 1608KL, 2004KL, 2106KL, 2404KL, 2406GL, BM4515, BM5115, BM5125 and BM6015 Series The conditions of shock test on the listed models are as belows
                                   Acceleration rate: 500 m/s2
                                   Application time:  11ms
                                   Once each in the X, Y and Z directions.
 
Locked Rotor
Protection
: The motor is protected from burnout in the locked rotor condition for 72 hours, at the rated voltage.
Polarity Protection : The fans are Reverse Polarity protected at the rated voltage.
Insulation Class : E class (UL: Class A)
Auto Restart : Most fan models provide current shut-down/auto restart function under locked rotor conditions.


■ Notes
Additional performance requirements may be determined between manufacturer and customer,
    based on customer's request.
Fans may be installed in a horizontal, vertical, or angled position.