[Skip to Content]

Previously Searched

CB004 series General Specs

CB004 series

CB004

Feature

  • Mid. capacity. OIML certification.

Specifications

General Spec.
Rated capacity98.07
N{10 kgf}~980.7 N{100 kgf}
Safe overload150 %R.C.
Ultimate overload200 %R.C.
Rated output2 mV/V±0.2 mV/V
Non-linearity0.015 %R.O.
Hysteresis0.015 %R.O.
Repeatability0.02 %R.O.
Creep0.02 %R.O./20 min
Creep recovery0.02 %R.O./20 min
Excitation, recommended12 V or less
Excitation, maximum20 V
Zero balance±0.1 mV/V
Input resistance375 Ω ~ 425 Ω
Output resistance345 Ω ~ 355 Ω
Insulation resistance2 000 MΩ or more (DC50
V)(between bridge and main body)
Temp. range, compensated-10 ℃ ~ 50 ℃
Temp. range, safe-10 ℃ ~ 50 ℃
Temp. effect on zero0.04 %R.O./10 ℃
Temp. effect on output0.012 %LOAD/10 ℃
Cableφ3.2, 4-cores shielded
40 cm cable directly attached, and cable end is
separated.
Class of protectionIP64 or equivalent
Material of elementAlluminium alloy
Durability1 000 000 times with
rated load applied.
Effect of eccentric load– Size of loading
plate is 400 mm x 400 mm at maximum.
– The center of loading plate and the center of
load cell should be the same position
– Error is within 0.01 %R.O. applied with 1/2 of
rated capacity at the position of 100 mm of eccentricity.

Table of P/N

Parts No.Rated capacityNatural frequencyRated displacementWeight
CB004-10K10 kg160 Hz0.55 mm350 g
CB004-15K15 kg200 Hz
CB004-20K20 kg230 Hz
CB004-25K25 kg250 Hz
CB004-30K30 kg270 Hz360 g
CB004-35K35 kg300 Hz
CB004-45K45 kg330 Hz370 g
CB004-60K60 kg380 Hz380 g
CB004-100K100 kg480 Hz390 g

Download

CAD files (DXF)Specification sheet (PDF)Instruction Manual (PDF)
CB004-*
(46KB)
No.KT51828-2-C
(54KB)
No.ENKT60245-1-G (31KB)
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here.
 

Connect with NMB Technologies Corporation