2 000 MΩ or more(DC50 V)(between bridge and main body)
Temp. range, compensated
-10 ℃ ~ 50 ℃
Temp. range, safe
-10 ℃ ~ 70 ℃
Temp. effect on zero
0.05 %R.O./10 ℃
Temp. effect on output
0.02 %LOAD/10 ℃
Cable
φ4.7, 4-cores shielded 164.5 cm cable directly attached, and cable end is separated.
Class of protection
IP64 or equivalent
Material of element
Alluminium alloy
Durability
1 000 000 times with rated load applied.
Effect of eccentric load
– Size of loading plate is 450 mm x 600 mm at maximum. – The center of loading plate and the center of load cell should be the same position – Error is within 0.02 %R.O. applied with 1/2 of rated capacity at the position of 150 mm of eccentricity.