[Skip to Content]

Low profile shear-web type UWV1

Low profile shear-web type UWV1

UWV1

Feature

  • Low profile, shear web type load cell.
    It is strong in lateral load and suitable to use in the limited space

Specifications

Rated capacity19.61
kN{2 tf}~980.7 kN{100 tf}
Safe overload150 %R.C.
Ultimate overload200 %R.C.
Rated output3 mV/V±0.0075 mV/V
Non-linearity0.1 %R.O. (UWV1-50T~100T : 0.2
%R.O.)
Hysteresis0.1 %R.O. (UWV1-50T~100T : 0.2
%R.O.)
Repeatability0.02 %R.O. (UWV1-50T~100T : 0.05
%R.O.)
Excitation, recommended12 V or less
Excitation, maximum20 V
Zero balance±0.03 mV/V
Input resistance350 Ω±3.5 Ω
Output resistance350 Ω±5 Ω
Insulation resistance2 000 MΩ or more (DC50 V) (between bridge and main body)
Temp. range, compensated-10 ℃ ~ 70 ℃
Temp. range, safe-20 ℃ ~ 80 ℃
Temp. effect on zero0.03 %R.O./10 ℃
Temp. effect on output0.03 %LOAD/10 ℃
Cableφ10, 4-cores shielded 3 m cable directly attached, Y-crimp type terminal lugs are attached at cable
end.
Class of protectionIP64 or equivalent
Material of elementAlloy steel
PaintPainted with epoxy
resin.
(Munsell 6GY3.5/2 half-polished resemblance color)
Durability1 000 000 times with
rated load applied.

Table of P/N

Parts No.Rated capacityNatural frequencyRated displacementWeight
UWV1-2T19.61 kN {2 tf}4 900Hz0.05 mmApprox.3.1 kg
UWV1-5T49.03 kN {5 tf}6 500 HzApprox.4 kg
UWV1-10T98.07 kN {10 tf}6 300 HzApprox.6.4 kg
UWV1-20T196.1 kN {20 tf}4 800 HzApprox.15.5 kg
UWV1-50T490.3 kN {50 tf}5 400 HzApprox.29 kg
UWV1-100T980.7 kN {100 tf}3 400 Hz0.09 mmApprox.74 kg

Download

CAD files (DXF)Specification sheet (PDF)Instruction Manual (PDF)
UWV1-2T (34KB)
UWV1-5T (34KB)
UWV1-10T (35KB)
UWV1-20T (36KB)
UWV1-50T (62KB)
UWV1-100T (64KB)
No.KT52997-2-A
(183KB)
No.KT60251-1 (49KB)
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here.
 