Ideal for weighing systems such as a tank, a hopper, or a floor scale. The combination with locker pin for automatic aligning function enables the high precision measurement. Approved OIML R60 Class C4. Accurate and reliable model (OIML-R60 Class C4 certified)
Specifications
OIML Standard
Accuracy class
OIML R60 C4
Maximum scale interval
4 000
Model (Capacity)
200K
300K
500K
1T
2T
3T
5T
Rated capacity
200 kg
300 kg
500 kg
1 ton
2 ton
3 ton
5 ton
Minimum detected scale (Vmin)
20 g
30 g
50 g
100 g
200 g
300 g
500 g
Safe overload
150 %R.C.
Ultimate overload
200 %R.C.
Rated output
3 mV/V±0.003 mV/V
Non-linearity
0.018 %R.O.
Hysteresis
0.018 %R.O.
Repeatability
0.010 %R.O.
Creep
0.012 %R.O./30 min
Creep recovery
0.012 %R.O./30 min
Excitation, recommended
10 V or less
Max. excitation
20 V
Zero balance
±0.03 mV/V
Input resistance
380 Ω ~ 460 Ω
Output resistance
345 Ω ~ 355 Ω
Insulation resistance
2 000 MΩ or more (DC50 V) (between bridge and main body)
Temp. range, compensated
-10 ℃ ~ 40 ℃
Temp. range, safe
-10 ℃ ~ 50 ℃
Temp. effect on zero
0.014 %R.O./10 ℃
Temp. effect on output
0.010 %LOAD/10 ℃
Cable
φ4.7, 4-cores shielded 6 m cable directly attached. with Y-crimp type terminal lugs at cable end.
Adobe Acrobat Reader is required to refer the Specification data sheet. Acrobat Reader is a registered trademark of Adobe Systems Ltd. The download of Adobe Acrobat Reader is here.