Mid capacity, tall profile. Accurate and reliable model with OIML R60 C3 certified.
Specifications
OIML Standard
Accuracy class
C3
Maximum scale interval
3 000
Model (Capacity)
6K
10K
15K
20K
25K
Rated capacity
6 kg
10 kg
15 kg
20 kg
25 kg
Minimum detected scale (Vmin)
0.6 g
1 g
1.5 g
2 g
2.5 g
Safe overload
150 %R.C.
Ultimate overload
200 %R.C.
Rated output
2 mV/V±0.2 mV/V
Non-linearity
0.015 %R.O.
Hysteresis
0.015 %R.O.
Repeatability
0.010 %R.O.
Creep
0.16 %R.O./30 min
Creep recovery
0.16 %R.O./30 min
Excitation, recommended
12 V or less
Excitation, maximum
20 V
Zero balance
±0.1 mV/V
Input resistance
400 Ω ~ 450 Ω
Output resistance
345 Ω ~ 355 Ω
Insulation resistance
2 000 MΩ or more (DC50 V) (between bridge and main body)
Temp. range, compensated
-10 ℃ ~ 40 ℃
Temp. range, safe
-10 ℃ ~ 40 ℃
Temp. effect on zero
0.014 %R.O./10 ℃
Temp. effect on output
0.012 %LOAD/10 ℃
Cable
φ3.2, 4-cores shielded 30 cm cable directly attached. Cable end separated.
Class of protection
IP40 or equivalent
Material of element
Alluminium alloy
Durability
1 000 00 times with rated load applied.
Effect of eccentric load
– The maximum size of loading plate : 400 mm x 600 mm – The center of loading plate and also center of load cell should be the same position – Error is withing 0.02 %R.O. applied with 1/2 of rated capacity at the position of 150 mm of eccentricity.
Adobe Acrobat Reader is required to refer the Specification data sheet. Acrobat Reader is a registered trademark of Adobe Systems Ltd. The download of Adobe Acrobat Reader is here.